Hi,
I have fiber channel and iscsi connectivity on F400
Can I present VV to the server using fiber channel and iscsi at the same time?
any effect on the server to determine the LUN
Present VV using fiber channel and iscsi at same time
Re: Present VV using fiber channel and iscsi at same time
I have fiber channel and iscsi connectivity on F400
Can I present VV to the server using fiber channel and iscsi at the same time?
If it works the same way as on a V-class then Yes, you can present a volume via both ways at the same time.
Re: Present VV using fiber channel and iscsi at same time
Hi,
what u mean by works the same way as on a V-class?
what u mean by works the same way as on a V-class?
Re: Present VV using fiber channel and iscsi at same time
zuwairi14 wrote:what u mean by works the same way as on a V-class?
I just meant that you are working on an F400 while I have experience only with a V800 (V-class). So my information may not apply to you (but it probably does).
Re: Present VV using fiber channel and iscsi at same time
V-Class , T-Class , F-Class if you can do it on a V-Class you can do it on a F-Class.
Same software only a bit different hardware
Same software only a bit different hardware
- Richard Siemers
- Site Admin
- Posts: 1333
- Joined: Tue Aug 18, 2009 10:35 pm
- Location: Dallas, Texas
Re: Present VV using fiber channel and iscsi at same time
Yes it should work.... I recommend making the FC path the primary and the iSCSI path a failover only... I wouldn't recommend round robin.
Richard Siemers
The views and opinions expressed are my own and do not necessarily reflect those of my employer.
The views and opinions expressed are my own and do not necessarily reflect those of my employer.